Technical Specifications

SI. No. Test Parameters Units Clause Test Method Test Results Requirements IS 5509:2000
1.
Dimensions & Tolerance
CL.8.0
IS 5509:2000
Length
mm
+2
+6/-0mm
Width
Mm
+1
+3/-0mm
Thickness
%
Β±1.41
Β±10%: upto 6mm Β±5%: 6mm & above
Squareness
%
0.08
Max 0.20
Edge Straightness
%
0.07
Max 0.20
2.
Moisture Content
%
CL.12.2
IS:1734-1983 (Part 1)
8-10
5-15
3.
Glue Adhesion in Dry State
CL.12.4
IS 5509:2000
Excellent
Min. Pass Std.
Glue Shear Strength
N
IS:1734-1983 (Part 4)
Avg. 1876 Min. 1798
Avg. 1350 Min. 1100
Adhesion of Piles
IS:1734-1983 (Part 5)
Excellent
Min. Pass Std
4.
Resistance to Water (at 72 hrs. Boiling Water)
CL.12.4
S 5509:2000
Excellent and Conforms to 72 hrs. Boiling
Min. Pass Std
Glue Shear Strength
N
IS:1734-1983 (Part 4 & 6)
Avg. 1565 Min. 1473
Avg. 1000 Min. 800
Adhesion of Piles
IS:1734-1983 (Part 5 & 6)
Excellent
Min. Pass Std.
5.
Mycological Test
CL.12.4
IS:1734-1983 (Part 4 & 7)
Excellent
Min. Pass Std
Glue Shear Strength
N
Avg. 1560 Min. 1352
Avg. 1000 Min. 800
Adhesion of Piles
IS:1734-1983 (Part 5 & 7)
Excellent
Min. Pass Std
6.
Static Bending Strength
CL.12.4
IS:1734-1983 (Part 11)
A). Modulus of Rupture
N/MMΒ²
a). Along the Grain
i). Average
57.86
Min. 50
ii). Min. Ind
50.32
Min. 45
b). Across the Grain
N/MMΒ²
i). Average
39.92
Min. 30
ii). Min. Ind.
35.76
Min. 27
B). Modulus of Elasticity
a). Along the Grain
N/MMΒ²
i). Average
8143
Min. 7500
ii). Min. Ind.
7837
Min. 6700
b). Across the Grain
N/MMΒ²
i). Average
4981
Min. 4000
ii). Min. Ind.
4856
Min. 3600
7.
Flammability Test
Minutes
CL.12.3.1
IS 5509:2000
50
30
8.
Flame Penetration Test
Minutes
CL.12.3.2
IS 5509:2000
50
47
9.
Rate of Burning
Minutes
CL.12.3.3
IS 5509:2000
60
20